RE-2Y(St)H&RE-2X(St)H
RE-2Y(St)H&RE-2X(St)H

RE-2Y(St)H&RE-2X(St)H

Über dieses Produkt

WebsiteBesuchen Sie die Produktseite
HALOGEN-FREE INSTRUMENTATION CABLES, Acc. to BS 5308 PART 1 TYPE 1RE-2Y(St)H,SİNGLE & MULTİ-TRIPLE, PE INSULATED, COLLECTİVE SCREENED, LSZH SHEATHEDRE-2X(St)H,SİNGLE & MULTİ-TRIPLE, XLPE INSULATED, COLLECTİVE SCREENED, LSZH SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. No corrosive gases are emitted in the event of fire. With blue sheath it is suitable for intrinsically safe systems. These cables are not recommended for direct burial. They are for indoor and oudoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain annealed copper wire, BS 6360, 0,50 mm2 and 1,0 mm2 solid, 0,50 mm2 and, 0,75 mm2 flexible or 1,5 mm2 stranded Insulation (2Y): PE compound, BS 6234 Type03 (RE-2Y….) Insulation (2X): XLPE compound, GP8, BS 7655 (RE-2X….) Core identification: Black / White / Red cores are numbered, (1-1-1, 2-2-2,…), Note: Other core configurations manufactured upon request Lay-up: Triples laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over tinned copper drain wire 0,50 mm2 Outer sheath: LSZH compound, LST1, BS 7655, LSZH : Low Smoke Zero Halogen Sheath colour: RAL 9005, Black or RAL 5015, Blue Triple: Three conductors twisted to a triple Standard: Designed acc. to BS 5308 Part 1 Type 1 Insulation thickness: 0,50mm2 : 0,50mm, 1,0mm2 : 0,60mm, 0,50mm2 : 0,60mm, 0,75mm2 : 0,60mm, 1,50mm2 : 0,60mm Conductor class, BS 6360: 0,50mm2 : Class 1, 1,0mm2 : Class 1, 0,50mm2 : Class 5, 0,75mm2 : Class 5, 1,5mm2 : Class 2 Conductor resistance: 0,50mm2 : 36,8 Ω/km, 1,0mm2 : 18,4 Ω/km, 0,50mm2 : 39,7 Ω/km, 0,75mm2 : 26,5 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Capacitance unbalance: (1 kHz) : max. 250 pF/250 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,5mm2 : 40 µH/Ω Rated voltage: 300/500V Test voltage: Urms core-core : 1000 V, Urms core-screen : 1000 V Temperature range (2Y): operation : - 40 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 40 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 6 x D Flame retardance test: IEC 60332-1 & BS EN 60332-1, IEC 60332-3 & BS EN 50266-2-4 Smoke density test: IEC 61034-2 & BS EN 61034-2 Halogen-free properties test: IEC60754-1/2 & BS EN 50267-2
Ähnliche Produkte
1/15
RE-2Y(St)H & RE-2X(St)H
RE-2Y(St)H & RE-2X(St)H
HALOGEN-FREE INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)H,SINGLE & MULTI-TRIPLE, PE INSULATED, COLLECTIVE SCREENED, HFFR SHEATHEDRE-2X(St)H,SINGLE & M...
DE-72175 Dornhan
RE-2Y(St)Y-fl & RE-2X(St)Y-fl
RE-2Y(St)Y-fl & RE-2X(St)Y-fl
INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)Y-fl,SINGLE & MULTI-TRIPLE, PE INSULATED, COLLECTIVE SCREENED, PVC SHEATHEDRE-2X(St)Y-fl,SINGLE & MULTI-TRI...
DE-72175 Dornhan
RE-2Y(St)Y-fl
RE-2Y(St)Y-fl
INSTRUMENTATION CABLES, Acc. to BS 5308 PART 1 TYPE 1SİNGLE & MULTİ-TRIPLE, PE INSULATED, COLLECTİVE SCREENED, PVC SHEATHED These cables are used for...
DE-72175 Dornhan
RE-2Y(St)H-TIMF&RE-2X(St)H-TIMF
RE-2Y(St)H-TIMF&RE-2X(St)H-TIMF
HALOGEN-FREE INSTRUMENTATION CABLES, Acc. to BS 5308 PART 1 TYPE 1RE-2Y(St)H-TIMF,MULTI-TRIPLE, PE INSULATED, INDIVIDUAL & COLLECTİVE SCREENED, LSZH S...
DE-72175 Dornhan
RE-Y(St)Y-fl & RE-Yw(St)Yw-fl MP
RE-Y(St)Y-fl & RE-Yw(St)Yw-fl MP
INSTRUMENTATION CABLES, EN 50288-7SİNGLE & MULTİ-PAİR, PVC INSULATED, COLLECTİVE SCREENED, PVC SHEATHED These cables are used for transmission of ana...
DE-72175 Dornhan
RE-2Y(St)YSWAY-fl-TIMF & RE-2X(St)YSWAY-fl-TIMF
RE-2Y(St)YSWAY-fl-TIMF & RE-2X(St)YSWAY-fl-TIMF
INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)YSWAY-fl-TIMF,MULTI-TRIPLE, PE INSULATED, INDIVIDUAL & COLLECTİVE SCREENED, ARMOURED, PVC SHEATHEDRE-2X(St)...
DE-72175 Dornhan
RE-2Y(St)Y & RE-2X(St)Y
RE-2Y(St)Y & RE-2X(St)Y
INSTRUMENTATION CONTROL CABLES, EN 50288-7RE-2Y(St)Y,ÇOK DAMARLI, PE YALITIMLI, GENEL EKRANLI, PVC KILIFLIRE-2X(St)Y,ÇOK DAMARLI, XLPE YALITIMLI, GENE...
DE-72175 Dornhan
RE-2Y(St)HSWAH & RE-2X(St)HSWAH
RE-2Y(St)HSWAH & RE-2X(St)HSWAH
HALOGEN-FREE INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)HSWAH,SINGLE & MULTI-TRIPLE, PE INSULATED, COLLECTIVE SCREENED, ARMOURED, HFFR SHEATHEDRE-2X(S...
DE-72175 Dornhan
RE-2Y(St)Y-fl-TIMF & RE-2X(St)Y-fl-TIMF
RE-2Y(St)Y-fl-TIMF & RE-2X(St)Y-fl-TIMF
INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)Y-fl-TIMF,MULTİ-TRIPLE, PE INSULATED, INDIVIDUAL & COLLECTİVE SCREENED, PVC SHEATHEDRE-2X(St)Y-fl-TIMF,MULT...
DE-72175 Dornhan
RE-Y(St)Y-fl-TIMF & RE-Yw(St)Yw-fl-TIMF
RE-Y(St)Y-fl-TIMF & RE-Yw(St)Yw-fl-TIMF
INSTRUMENTATION CABLES, EN 50288-7MULTİ-TRIPLE, PVC INSULATED, INDIVIDUAL & COLLECTİVE SCREENED, PVC SHEATHED These cables are used for transmission ...
DE-72175 Dornhan
RE-2Y(St)H & RE-2X(St)H MP
RE-2Y(St)H & RE-2X(St)H MP
HALOGEN-FREE INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)H,SINGLE & MULTI-PAIR, PE INSULATED, COLLECTIVE SCREENED, HFFR SHEATHEDRE-2X(St)H,SINGLE & MUL...
DE-72175 Dornhan
RE-2Y(St)Y-fl-TIMF
RE-2Y(St)Y-fl-TIMF
INSTRUMENTATION CABLES, Acc. to BS 5308 PART 1 TYPE 1MULTİ-TRIPLE, PE INSULATED, INDIVIDUAL & COLLECTİVE SCREENED, PVC SHEATHED These cables are used...
DE-72175 Dornhan
RE-2G(St)H-CI  FE180 MP
RE-2G(St)H-CI FE180 MP
HALOGEN-FREE FIRE RESISTANT (CI) INSTRUMENTATION CABLES, EN 50288-7SINGLE & MULTI-PAIR, SILICONE INSULATED, COLLECTIVE SCREENED, HFFR SHEATHED These ...
DE-72175 Dornhan
RE-2Y(St)HSWAH&RE-2X(St)HSWAH
RE-2Y(St)HSWAH&RE-2X(St)HSWAH
HALOGEN-FREE INSTRUMENTATION CABLES, Acc. to BS 5308 PART 1 TYPE 2RE-2Y(St)HSWAH,SINGLE & MULTI-TRIPLE, PE INSULATED, COLLECTİVE SCREENED, LSZH SHEATH...
DE-72175 Dornhan
RE-2Y(St)H-PIMF & RE-2X(St)H-PIMF
RE-2Y(St)H-PIMF & RE-2X(St)H-PIMF
HALOGEN-FREE INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)H-PIMF,MULTI-PAIR, PE INSULATED, INDIVIDUAL & COLLECTIVE SCREENED, HFFR SHEATHEDRE-2X(St)H-PIM...
DE-72175 Dornhan
Trend-Produkte
1/15
STAHLWERK Druckluft Kompressor ST 510 pro – 10 Bar
STAHLWERK Druckluft Kompressor ST 510 pro – 10 Bar
STAHLWERK Schweissgeräte GmbH
DE-53332 Bornheim
yun express
yun express
Meine Sendungsverfolgung
DE-18439 Stralsund
L&M Paris Bordkoffer
L&M Paris Bordkoffer
Gerhardt's-Neuheiten Inh. Hans-Peter Gerhardt
DE-36266 Heringen
Waldkindergarten-Wagen
Waldkindergarten-Wagen
WEHA FAHRZEUG- & CONTAINERBAU GMBH & CO. KG
DE-78234 Engen
Ankauf von Leiterplatten-Schrott / Platinen-Schrott / PC-Schrott
Ankauf von Leiterplatten-Schrott / Platinen-Schrott / PC-Schrott
HB-Elektroschrottrecycling
DE-65779 Kelkheim (Taunus)
Ankauf KFZ Kompletträder Reifen Räder Felgen
Ankauf KFZ Kompletträder Reifen Räder Felgen
Lagerclean GmbH
DE-33129 Delbrück
Hochgras Aufsitzmäher mit Allradantrieb
Hochgras Aufsitzmäher mit Allradantrieb
Erich Mayer LKW-Verleih GmbH
DE-74076 Heilbronn
Kaminofen kaufen
Kaminofen kaufen
Feuer hoch 3
DE-86500 Kutzenhausen
DHL Sendugsverfolgung
DHL Sendugsverfolgung
Meine Sendungsverfolgung
DE-18439 Stralsund
IVG2400 Pods Großhandel ab 4,50€
IVG2400 Pods Großhandel ab 4,50€
Andreas Shimf
DE-21031 Hamburg
Auto Hebebühne 2500kg 15cm flach
Auto Hebebühne 2500kg 15cm flach
fradashop GmbH
DE-49716 Meppen
Neue Eichen-Schwellen - Eisenbahnschwellen
Neue Eichen-Schwellen - Eisenbahnschwellen
Baka-Holz Holzgroßhandel für den Gartenbau GmbH
DE-46238 Bottrop